2020 官網升級中!現在您訪問官網的瀏覽器設備分辨率寬度低于1280px請使用高分辨率寬度訪問。
The impact of lightning (indirect lightning) in nature and voltage changes caused by large switch switching in power supply lines on power supply lines and communication lines is particularly large, and the impact on products may be destructive. The lightning surge generator is used to evaluate the performance of the equipment when it is subjected to high-energy disturbance from the power line port and other signal line ports. The product meets the requirements of new standards such as iec61000-4-5 and gb/t17626.5.
Product model:
Surge waveform
Open circuit voltage
short-circuit current
Surge polarity
Phase angle
Programmable test program
Output impedance
Coupling / decoupling network
Surge coupling mode
frequency
Interval time
Working power supply
ambient temperature
SUR S8
Voltage wave: 1.2/50 main 20%us current wave: 8/20 main 20%us
0.2~8kv main 5%
0.1~4kA±5%
Positive, negative, positive / negative, negative / positive, alternating positive and negative,
0~360 ° synchronous or asynchronous make-up 1 °
Built in IEC standard, user-defined, programming, up to 40 groups
2q (common mode 12q2)
Built in, single-phase three wire, 16a, 50hz/60hz
Differential mode 18uf/2q, common mode 9uf /10q
1 ~ 9999 times
10~9999s
AC220V±10%; 50/60Hz 150W
Temperature: 15 ℃ ~35 ° ℃; Relative humidity 10%-70%